IRt/c.1X

Product Overview

The
IRt/c.1X
Features

• Infrared Thermocouple IRt/c

• Non-contact

• Self-powered

• Intrinsically Safe

• Repeatability 0.02°F (0.01°C)

• Interchangeability ±1%

• Resolution approx. 0.0001°C

• Small Size

Technical Data

Sensing Range
-50 to 1200°F (-45 to 650°C)
Ambient Temperature Range
0 to 212°F (-18 to 100°C)
Optimum Range Selections
Eight models per t/c type (see Temperature Selection Chart)
Field of View
approximately 1:1 (60°)
Minimum Spot Size
.3” (8mm)
Spectral Response
6.5 to 14µm
Output Impedance
3 Kohms approx
Tubing Size Range
Response Time
100 Milliseconds
Dimensions
1.43” x .50” Dia. (36 x 12.7mm)
Housing
Stainless steel, hermetically sealed, exceeds NEMA 4,4X; IP65, 67, cable shield grounded to housing and electrically isolated from signal
Cable
Twisted shielded pair of base thermocouple material (J,K,E,T), 3ft (.9m) std lenght, Telfon sheated, reated to 392°F (200°C) continuous service
Air Purge
Input Device Compatibility
Weight
1.4oz. (40 grams) with cable

Calibration

Ordering information IRt/c.1X-* (Thermocouple Type) - (Precalibrated Temperature Range). Thermocouple type J,K,E,T over temperature range specified.
Download this Data Sheet as PDFDownload the Instructions Manual of the Novus here